USS-600

Uniform Source Systems

FEATURES (USS-600) -
Stepped or continuous radiance variability
from 5 to 2,800 cd/m2
Spectraflect® interior provides better than
98% radiance uniformity
Satellite sphere improves uniform input
into main sphere
Interchangeable components
Radiometric and photometric
calibration reports
NIST traceable luminance calibration
Backed by an ISO 9001:2000 Registered
Quality Management System

FEATURES (USS-800C) -
Continuous radiance variability from
0 to 9800, 13500, or 24000 cd/m2
Spectraflect interior provides >98%
radiance uniformity
Radiometric and photometric
calibration reports
NIST traceable luminance calibration
Backed by an ISO 9000:2001 registered
quality management system

FEATURES (USS-2000C) -
Stepped or Continuous Radiance Variability
Better than 98% Radiance Uniformity
Spectraflect® Interior
Interchangeable Components
Calibration Reports
NIST Traceable Luminance Calibration
Control Software
Backed by ISO 9001:2000 Registered Quality
Management System
  • 型號
  • 產品概述
  • 庫存
  • 詢價數量
  • 詢價車
AS-02451-201

USS 600S, Small Uniform Source Systems

  •  Sphere Diameter  6 in (15 cm)
     Exit Port Diameter  2 in (5 cm)
     Sphere Coating Reflectance  98%
     Luminance Range (cd/m2)  15 – 2800
     Luminance Range (ft-L)  5 - 800
     Illuminance Range (lux)  60 – 8700
     Peak Radiance
     (mW/cm2-sr-
    μm at 0.9 μm)
     8.0
     Luminance Uniformity *  >98%
     Sphere Dimension: (W x D x H)  9.83 x 10.0 x 11.7 in (25 x 25 x 30 cm)

     

  • * Applies at maximum radiance, uniformity may vary at lower radiance levels.

加入
AS-02451-301

USS 600C, Small Uniform Source Systems

  •  Sphere Diameter  6 in (15 cm)
     Exit Port Diameter  2 in (5 cm)
     Sphere Coating Reflectance  98%
     Luminance Range (cd/m2)  0- 2100
     Luminance Range (ft-L)  0- 600
     Illuminance Range (lux)  0 – 6600
     Peak Radiance
     (mW/cm2-sr-
    μm at 0.9 μm)
     6.0
     Luminance Uniformity *  >98%
     Sphere Dimension: (W x D x H)  9.83 x 10.0 x 11.7 in (25 x 25 x 30 cm)

     

  • * Applies at maximum radiance, uniformity may vary at lower radiance levels.

加入
AS-02711-100

USS-800C-035R, USS-800C Continuous Uniform Source System

  •  Sphere Diameter  8 in (20 cm)
     Exit Port Diameter  2 in (5 cm)
     Sphere Coating Reflectance  98%
     Luminance Range (cd/m2)  0 - 9800
     Luminance Range (ft-L)  0 - 2800
     Illuminance Range (lux)  0 - 30000
     Peak Radiance
     (mW/cm2-sr-
    μm at 0.9 μm)
     24
     Luminance Uniformity *  >98%

     

  • * Applies at maximum radiance, uniformity may vary at lower radiance levels.

加入
AS-02711-200

USS-800C-075R, USS-800C Continuous Uniform Source System

  •  Sphere Diameter  8 in (20 cm)
     Exit Port Diameter  2 in (5 cm)
     Sphere Coating Reflectance  98%
     Luminance Range (cd/m2)  0 - 13500
     Luminance Range (ft-L)  0 - 4000
     Illuminance Range (lux)  0 - 42000
     Peak Radiance
     (mW/cm2-sr-
    μm at 0.9 μm)
     52
     Luminance Uniformity *  >98%

     

  • * Applies at maximum radiance, uniformity may vary at lower radiance levels.

加入
AS-02711-300

USS-800C-100R, USS-800C Continuous Uniform Source System

  •  Sphere Diameter  8 in (20 cm)
     Exit Port Diameter  2 in (5 cm)
     Sphere Coating Reflectance  98%
     Luminance Range (cd/m2)  0 - 24000
     Luminance Range (ft-L)  0 - 7200
     Illuminance Range (lux)  0 - 75000
     Peak Radiance
     (mW/cm2-sr-
    μm at 0.9 μm)
     69
     Luminance Uniformity *  >98%

     

  • * Applies at maximum radiance, uniformity may vary at lower radiance levels.

加入
AS-02448-201

USS-1200S, Medium USS Uniform Source Systems

  • Technical Specification Differences

     Luminance Range: (x1,000 cd/m2)  10, 20, 30, 40
     Peak Radiance
     (mW/cm2-sr-
    μm at 0.9 μm)
     98.5
     Color Temperature  3000K

    For All Systems

     Integrating Sphere  Uniform Source Integrating Sphere
     Sphere Coating
     Spectraflect®
     Sphere Coating Reflectance  98%
     Luminance Uniformity *  >98%

    System Configuration

     Sphere Diameter  12 in (30 cm)
     Exit Port
     4 in (10 cm)
     Lamp Assembly * Power  Qty 4, 35 W
     Power Supplies  Qty 4, for 35 W lamps
     Current Stability  3.07 A +/- 0.1%
     Sphere Dimension: (W x D x H)  17.1 x 11.3 x 19.7 in
     (43.4 x 28.7 x 50.0 cm)
     Rack Dimension: (W x D x H)
     19.7 x 21.7 x 21.9 in
     (50 x 55 x 56 cm)

     

  • * Applies at maximum radiance, uniformity may vary at lower radiance levels.

加入
AS-02448-301

USS-1200C, Medium USS Uniform Source Systems

  • Technical Specification Differences

     Luminance Range: (x1,000 cd/m2)  0 - 40
     Peak Radiance
     (mW/cm2-sr-
    μm at 0.9 μm)
     98.5
     Color Temperature  3000K

    For All Systems

     Integrating Sphere  Uniform Source Integrating Sphere
     Sphere Coating
     Spectraflect®
     Sphere Coating Reflectance  98%
     Luminance Uniformity *  >98%

    System Configuration

     Sphere Diameter  12 in (30 cm)
     Exit Port
     4 in (10 cm)
     Lamp Assembly * Power  Qty 3, 35 W
     Qty 1, 100 W
     Power Supplies  Qty 3, for 35 W lamps
     Qty 1, for 100 W lamp
     Current Stability  3.07 A +/- 0.1%
     8.33 A +/- 0.1%
     Sphere Dimension: (W x D x H)  17.1 x 11.3 x 19.7 in
     (43.4 x 28.7 x 50.0 cm)
     Rack Dimension: (W x D x H)
     19.7 x 21.7 x 21.9 in
     (50 x 55 x 56 cm)

     

  • * Applies at maximum radiance, uniformity may vary at lower radiance levels.

加入
AS-02444-201

USS-2000S, Medium USS Uniform Source Systems

  • Technical Specification Differences

     Luminance Range: (x1,000 cd/m2)  4.6, 9.2, 13.8, 18
     Peak Radiance
     (mW/cm2-sr-
    μm at 0.9 μm)
     55
     Color Temperature  3000K

    For All Systems

     Integrating Sphere  Uniform Source Integrating Sphere
     Sphere Coating
     Spectraflect®
     Sphere Coating Reflectance  98%
     Luminance Uniformity *  >98%

    System Configuration

     Sphere Diameter  20 in (50 cm)
     Exit Port
     8 in (20 cm)
     Lamp Assembly * Power  Qty 4, 35 W
     Power Supplies  Qty 4, for 35 W lamps
     Current Stability  3.07 A +/- 0.1%
     Sphere Dimension: (W x D x H)  24 x 18.5 x 23.8 in
     (61 x 47 x 60 cm)
     Rack Dimension: (W x D x H)
     19.7 x 21.7 x 21.9 in
     (50 x 55 x 56 cm)

     

  • * Applies at maximum radiance, uniformity may vary at lower radiance levels.

加入
AS-02444-301

USS-2000C, Medium USS Uniform Source Systems

  • Technical Specification Differences

     Luminance Range: (x1,000 cd/m2)  0 - 18
     Peak Radiance
     (mW/cm2-sr-
    μm at 0.9 μm)
     55
     Color Temperature  3000K

    For All Systems

     Integrating Sphere  Uniform Source Integrating Sphere
     Sphere Coating
     Spectraflect®
     Sphere Coating Reflectance  98%
     Luminance Uniformity *  >98%

    System Configuration

     Sphere Diameter  20 in (50 cm)
     Exit Port
     8 in (20 cm)
     Lamp Assembly * Power  Qty 3, 35 W
     Qty 1, 100 W
     Power Supplies  Qty 3, for 35 W lamps
     Qty 1, for 100 W lamp
     Current Stability  3.07 A +/- 0.1%
     8.33 A +/- 0.1%
     Sphere Dimension: (W x D x H)  24 x 18.5 x 23.8 in
     (61 x 47 x 60 cm)
     Rack Dimension: (W x D x H)
     19.7 x 21.7 x 21.9 in
     (50 x 55 x 56 cm)

     

  • * Applies at maximum radiance, uniformity may vary at lower radiance levels.

加入

USS 600 Small Uniform Source Systems

Spectral Radiance Plot

Specifications

Description and Model USS 600S  USS 600C
 6 inch Uniform Source System  AS-02451-201  AS-02451-301
 System Includes
 6 inch Uniform Source Sphere, US-060-SF AS-02451-100 AS-02451-100
 Internal Halogen Lamp Assembly*, IHLS-100-035 AS-02631-035 AS-02631-035
 Preset Power Supply*, LPS-100-0307 AS-02600-307 AS-02600-307
 Photopic Detector, SDA-050-P-RTA-CX AS-02522-401 AS-02522-401
 Radiometer/Photometer*, SC 6000
AS-02702-100 AS-02702-100
 Iris Diffuser (S Series only) AS-02452-000 -
 Variable Attenuator, VA-100-SC (C Series only) - AS-02450-100
 Motor Controller*, MC-1000 (C Series only) - AS-02609-000
 SCC-LU Luminance Calibration SCC-LU SCC-LU
 Detector Vl Filter Silicon Photodiode Vl Filter Silicon Photodiode
 Active Area 5.7 mm2 5.7 mm2
 Range Visible Visible
 f1’ 4% 4%
 Connector BNC BNC
 Radiometer/Photometer SC 6000 SC 6000
 Power Requirements 110./220 VAC, 50/60 Hz 110./220 VAC, 50/60 Hz
 Current Dynamic Range 1 pA – 1 mA 1 pA – 1 mA
 Voltage Dynamic Range 10 mVdc – 50 Vdc- 10 mVdc – 50 Vdc-
 Computer Interface Ethernet Ethernet
 Lamp Assemblies IHLS-100-035 IHLS-100-035
 Power Qty 1, 35 W Qty 1, 35 W
 Color Temperature 3000K 3000K
 Power Supplies LPS-100-0307 LPS-100-0307
 Power Requirements 110./220 VAC, 50/60 Hz 110./220 VAC, 50/60 Hz
 Current Stability 3.07 A +/- 0.1% 3.07 A +/- 0.1%
 Current Rise Time 20 s 20 s
 Weight 6.5 lbs. (2.9 kg.) 6.5 lbs. (2.9 kg.)
 Dimension: (W x D x H) 8.3 x 10.5 x 3.5 in
(21.1 x 26.7 x 8.9 cm)
8.3 x 10.5 x 3.5 in
(21.1 x 26.7 x 8.9 cm)
 Compliance CE CE
 Recommended Computer Requirements
 Operating System Windows 98® 2nd Edition, Windows 2000® PE or later
 Drives 3 1/2 in Disk Drive, CD-ROM Drive
 Optional Accessories/Calibrations
 Labsphere Light Source Assemblies IHLS/EHLS Series
 Labsphere Power Supplies LPS Series
 Spectral Radiance Calibrations (300-2400 nm) USC-SR
 Radiance Calibration SCC-RA
 Exit Port Luminance Uniformity Mapping USC-PM
 Illuminance Calibration SCC-IL
 Custom Spectral Radiance Calibrations Optional
 Rack Mounted Electronics Optional

 

USS-800C continuous Uniform Source System

Spectral Radiance Plot

Specifications

Description and Model USS-800C-035R  USS-800C-075R USS-800C-100R
 USS-800C 8 inch Continuous Uniform Source System  AS-02711-100  AS-02711-200 AS-02711-300
 System Includes
 8 inch Uniform Source Sphere, USS-800-SF
AS-02465-000 AS-02465-000 AS-02465-000
 External Halogen Lamp Supply, EHLS-100-35R, 75R, 100R AS-02630-035 AS-02630-075 AS-02630-100
 Preset Power Supply, LPS-100-0307, 0625, 0833 AS-02600-307 AS-02600-625  AS-02600-833
 Photopic Detector, SDA-050-P-RTA-CX AS-02522-301 AS-02522-301  AS-02522-301
 Variable Attenuator, VA-100-MIC
AS-02455-000 AS-02455-000  AS-02455-000
 Radiometer/Photometer, SC 6000 AS-02702-000 AS-02702-000  AS-02702-000
 Luminance Calibration, SCC-LU SCC-LU SCC-LU  SCC-LU
 Detector Vl Filter Silicon Photodiode
 Active Area 5.7 mm2
 Range Visible
 f1’ 4%
 Connector BNC
 Radiometer/Photometer SC 6000
 Power Requirements 110./220 VAC, 50/60 Hz
 Current Dynamic Range 1 pA – 1 mA
 Voltage Dynamic Range 10 mVdc – 50 Vdc-
 Computer Interface Ethernet
 Lamp Assemblies EHLS-100-035R EHLS-100-075R  EHLS-100-100R
 Power Qty 1, 35 W Qty 1, 75 W Qty 1, 100 W
 Reflector Rhodium Rhodium Rhodium
 Color Temperature 3000K 3000K  3000K
 Power Supplies LPS-100-0307 LPS-100-0625 LPS-100-0833
 Power Requirements 110./220 VAC, 50/60 Hz 110./220 VAC, 50/60 Hz 110./220 VAC, 50/60 Hz
 Current Stability 3.07 A +/- 0.1% 6.25 A +/- 0.1%  8.33 A +/- 0.1%
 Current Rise Time 20 s 20 s  20 s
 Weight 6.5 lbs. (2.9 kg.) 6.5 lbs. (2.9 kg.) 6.5 lbs (2.9 kg)
 Dimension: (W x D x H) 8.3 x 10.5 x 3.5 in
(21.1 x 26.7 x 8.9 cm)
8.3 x 10.5 x 3.5 in
(21.1 x 26.7 x 8.9 cm)
 8.3 x 10.5 x 3.5 in
(21.1 x 26.7 x 8.9 cm)
 Compliance CE CE  CE
 Recommended Computer Requirements
 Operating System Windows 98® 2nd Edition, Windows 2000® PE or later
 Drives CD-ROM Drive
 Ports TCP/IP
 Optional Calibrations
 Standard Spectral Radiance Calibrations USC-SR (300-2400 nm)
 Radiance Calibration SCC-RA
 Exit Port Luminance Uniformity Mapping USC-PM
 Illuminance Calibration SCC-IL

 Custom Spectral Radiance Calibrations Optional

 

Medium USS Uniform Source Systems

Spectral Radiance Plot

Specifications

Description and Model USS-1200  USS-2000
 Stepped Uniform Source System (USS-S)  AS-02448-201  AS-02444-201
 Continuous Uniform Source System (USS-C) AS-02448-301 AS-02444-301
 System Includes
 Uniform Source Sphere, US-120-SF or US-200-SF AS-02448-000 AS-02444-000
 Internal Halogen Lamp Assemblies*, IHLS-100-035 AS-02631-035 AS-02631-035
 Preset Power Supply*, LPS-100-0307 AS-02600-307 AS-02600-307
 External Halogen Lamp Assemblies*,
 EHLS-100-100R
AS-02630-100 AS-02630-100
 Preset Power Supplies*, LPS-100-0833
AS-02600-833 AS-02600-833
 Photopic Detector, SDA-050-P-RTA-CX AS-02522-401 AS-02522-401
 Variable Attenuator (C Series), VA-100-SC AS-02450-100 AS-02450-100
 Motor Controller* (C Series), MC-1000 AS-02702-000 AS-02702-000
 Radiometer/Photometer*, SC 6000 AS-01636-100 AS-01636-100
 Luminance Calibration SCC-LU SCC-LU
 Detector Vl Filter Silicon Photodiode
 Active Area 5.7 mm2
 Range Visible
 f1’ 4%
 Connector BNC
 Radiometer/Photometer SC 6000
 Power Requirements 110./220 VAC, 50/60 Hz
 Current Dynamic Range 1 pA – 1 mA
 Voltage Dynamic Range 10 mVdc – 50 Vdc-
 Computer Interface Ethernet
 Lamp Power Supply LPS-100
 Power Requirements 110./220 VAC, 50/60 Hz
 Current Rise Time 20 s
 Compliance CE
 Optional Accessories/Calibrations
 Internal & External Light Source Assemblies IHLS (internal)/EHLS (external)
 Power Supplies LPS
 Spectral Radiance Calibration USC-SR (300-2400 nm)
 Radiance Calibration SCC-RA
 Exit Port Luminance Uniformity Mapping USC-PM
 Illuminance Calibration SCC-IL
 Custom Spectral Radiance Calibrations Optional
 Recommended Computer Requirements
 Operating System Windows 98® 2nd Edition, Windows 2000® PE or later
 Drives 3 1/2” Disk Drive or 1 CD-ROM Drive